Schlage ALX53P SPA Grade-2 Cylindrical Lever Lock, Entrance Function, Sparta Lever

Perfectly suited to the ND grade 1 series, ALX also allows you to seamlessly suite between the two to gain grade 1 strength, security, and functionality when and where you need it.

ANSI Function F109 – Key cylinder outside; push/turn button inside; deadlatch. Inside button locks outside lever by pushing button or pushing and turning button. Pushed button: unlock with key outside or by rotating inside lever. Pushed/turned button: key outside retracts latch only; unlock by returning inside button to home position then using key or rotating inside lever. Inside lever always free for immediate egress.

  • For medium to heavy-duty commercial door applications
  • Field selectable Vandlgard® feature - Converts to ALXV53
  • Accommodates 1-3/8" to 1-3/4" door thickness with minimal chassis adjustment
  • Deep-drawn spindle with 5 points of lever engagement minimizes droop and wobble
  • Grade 1 compression springs

codes

Brand

Finishes

626 Satin Chrome, 605 Bright Brass, 606 Satin Brass, 622 Matte Black, 612 Satin Bronze, 613 Oil Rubbed Bronze, 625 Bright Chrome, 643e Aged Bronze, 619 Satin Nickel, 626AM Satin Chrome Antimicrobial

Lock Function

Entry (Entrance)

Cylinder & Keys

5-pin or 6-pin conventional, keyed different, with 2 keys

Keyway

Schlage C Keyway, Schlage S123 Keyway

Lever Design

SPA (Sparta)

Backset

2-3/4"

Latch

1/2” throw, deadlocking - 1-1/8" x 2-1/4" face

Strike

4-7/8” x 1-1/4” ASA/ANSI strike with curved lip to meet ANSI A115.2 door frame preparation

Usage

Medium Duty

ANSI/BHMA Standard

Certified A156.2-2011 Series 4000, Grade 2; exceeds standard for lever and spindle strength and durability

ADA Compliance

Meets ADA requirements - A117.1 Accessibility Code

Fire-Rating

UL/cUL listed up to 3 Hours – UL symbol on the latch front

CA Fire Code

All levers with a return to door of 1 ⁄2" (64 mm) or less comply

FL Building Code

ASTM E330, E1886, E1996 and Miami Dade (TAS 201, 202, 203) requirements for hurricanes

Handing

Non-Handed

Door Thickness

1-3/8" to 1-3/4"

Warranty

10 Year Limited

SchlageALXInstallationInstructions SchlageALXSeriesInstallationInstructionsSpanish How to Install Von Duprin 98/99 Rim Exit Device
ALX53P SPA (Sparta) Entrance Lever Lock
Schlage ALX53P SPA (Sparta) Entrance Lever Lock