Schlage ALX53J ATH Grade-2 Cylindrical Lever Lock, Entrance Function, Athens Lever, Less Full Size Interchangeable Core

Perfectly suited to the ND grade 1 series, ALX also allows you to seamlessly suite between the two to gain grade 1 strength, security, and functionality when and where you need it.

Interchangeable core users can enjoy the convenience of fast rekeying without having to disassemble the lock. This feature is very useful in applications where a high frequency of core changes are needed.

ANSI Function F109 – Key cylinder outside; push/turn button inside; deadlatch. Inside button locks outside lever by pushing button or pushing and turning button. Pushed button: unlock with key outside or by rotating inside lever. Pushed/turned button: key outside retracts latch only; unlock by returning inside button to home position then using key or rotating inside lever. Inside lever always free for immediate egress.

  • 23-030 Full Size Interchangeable Core sold separately
  • For medium to heavy-duty commercial door applications
  • Field selectable Vandlgard® feature - Converts to ALXV53
  • Accommodates 1-3/8" to 1-3/4" door thickness with minimal chassis adjustment
  • Deep-drawn spindle with 5 points of lever engagement minimizes droop and wobble
  • Grade 1 compression springs

codes

Brand

Finishes

626 Satin Chrome, 605 Bright Brass, 606 Satin Brass, 622 Matte Black, 612 Satin Bronze, 613 Oil Rubbed Bronze, 625 Bright Chrome, 643e Aged Bronze, 619 Satin Nickel, 626AM Satin Chrome Antimicrobial

Lock Function

Entry (Entrance)

Lever Design

ATH (Athens)

Backset

2-3/4"

Latch

1/2” throw, deadlocking - 1-1/8" x 2-1/4" face

Strike

4-7/8” x 1-1/4” ASA/ANSI strike with curved lip to meet ANSI A115.2 door frame preparation

Usage

Medium Duty

ANSI/BHMA Standard

Certified A156.2-2011 Series 4000, Grade 2; exceeds standard for lever and spindle strength and durability

ADA Compliance

Meets ADA requirements - A117.1 Accessibility Code

Fire-Rating

UL/cUL listed up to 3 Hours – UL symbol on the latch front

FL Building Code

ASTM E330, E1886, E1996 and Miami Dade (TAS 201, 202, 203) requirements for hurricanes

Handing

Non-Handed

Door Thickness

1-3/8" to 1-3/4"

Warranty

10 Year Limited